Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 593
Filtrar
1.
Braz. J. Pharm. Sci. (Online) ; 59: e21077, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1429974

RESUMO

Abstract Teicoplanin is a glycopeptide antibiotic commonly used to treat Gram-positive bacterial infections in the clinic. The aim of this study was to provide a therapeutic reference for the clinical application and dosage regimen adjustment of teicoplanin by identifying factors associated with its plasma trough concentration (Ctrough). A retrospective study was performed on patients with suspected or documented Gram-positive infections who were hospitalized from November 2017 to January 2020 and treated with teicoplanin while undergoing routine therapeutic drug monitoring (TDM). A total of 112 Ctrough trough measurements were obtained from 72 patients were included in this study. SPSS software was used for correlation analysis and receiver operator characteristic curve (ROC) analysis. The Ctrough for teicoplanin showed statistically significant relationships (P<0.05) with PLT, Scr, CLcr, eGFR, BUN and Cys-C. ROC curve analysis revealed that CLcr and eGFR were more sensitive and specific for Ctrough compared to the other factors. These findings should be considered in the clinical application of teicoplanin and for its dosage adjustment.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Pacientes/classificação , Infecções por Bactérias Gram-Positivas/patologia , Teicoplanina/análise , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/instrumentação , Creatinina/efeitos adversos , Taxa de Filtração Glomerular
2.
Sci Rep ; 12(1): 1643, 2022 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-35102224

RESUMO

The aim of the study was to compare 3 blood sampling methods, including capillary blood sampling, for determining Tamoxifen (TAM), Z-endoxifen (END), and 4-hydroxytamoxifen (4HT) concentrations. High performance liquid chromatography-mass spectrometry was used to quantify concentrations of TAM, END, and 4HT in plasma, venous blood, and capillary blood samples of 16 participants on TAM therapy for breast cancer. The rhelise kit was used for capillary sampling. Calibration curves using 13C-labeled analogs of TAM, END, and 4HT as internal standards were used for quantifications. A capillary sampling kit was used successfully for all participants. Mean TAM concentrations did not differ significantly in the 3 types of samples. Mean END and 4HT concentrations did differ significantly between capillary and venous blood samples, possibly related to photodegradation in the internal standards prior to use or degradation products with chromatographic retention times similar to the metabolites. TAM, END, and 4HT concentrations were relatively stable when stored for 14 days at 8 °C and 20 °C. Therapeutic drug monitoring of TAM using an innovative kit and capillary blood sampling is feasible. Preliminary data from this study will aid in developing a multicenter, randomized clinical trial of personalized TAM dose monitoring and adjustments, with the goal of enhancing the quality-of-life and outcomes of patients with breast cancer.Clinical Trial Identification: EudraCT No 2017-000641-44.


Assuntos
Neoplasias da Mama/sangue , Monitoramento de Medicamentos/instrumentação , Antagonistas de Estrogênios/sangue , Kit de Reagentes para Diagnóstico , Tamoxifeno/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/tratamento farmacológico , Capilares , Cromatografia Líquida de Alta Pressão , Antagonistas de Estrogênios/uso terapêutico , Estudos de Viabilidade , Feminino , Humanos , Espectrometria de Massas , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Suécia , Tamoxifeno/sangue , Tamoxifeno/uso terapêutico
3.
Clin Biochem ; 100: 60-66, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34788637

RESUMO

INTRODUCTION: The type of blood collection tube used when obtaining samples for therapeutic drug monitoring (TDM) has important implications on the accuracy of results. Serum tubes without a gel separator are currently considered best practice. We sought to evaluate the performance of Barricor™, a novel plasma tube that utilizes an inert mechanical separator, as well as a gel-based tube (PST™) for testing acetaminophen, digoxin, gentamicin, methotrexate, phenobarbital, phenytoin, salicylate, vancomycin, valproic acid, carbamazepine, and theophylline on a Roche Cobas® 8000 platform. METHODS: Paired patient samples were collected from individuals taking at least one of the medications evaluated. These were supplemented with spiked specimens to ensure a minimum of 40 paired samples per drug. All drugs were measured within two hours of collection on Roche e602 or c502 instruments. Deming regression was used to assess bias between Barricor™ vs serum and PST™ vs serum. Seven-day refrigerated stability was also assessed in Barricor™, PST™, and serum tubes in a subset of samples (n = 10) for each drug. RESULTS: Drug concentrations in Barricor™ were similar to serum for each drug assessed. In contrast, a negative bias was observed in PST™ compared to serum tubes for carbamazepine (-7.6%) and phenytoin (-6.8%) although this did not surpass our total allowable error goal of 10%. All drugs recovered within ±10% of baseline value when samples were stored refrigerated for 7 days except for carbamazepine, phenytoin, and phenobarbital where significant analyte loss was observed within the first day in PST™ tubes. CONCLUSION: Barricor™ tubes are a suitable alternative to serum for TDM on the Roche Cobas® 8000 platform.


Assuntos
Preservação de Sangue , Coleta de Amostras Sanguíneas , Monitoramento de Medicamentos , Preservação de Sangue/instrumentação , Preservação de Sangue/métodos , Coleta de Amostras Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/métodos , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Humanos
4.
Braz. J. Pharm. Sci. (Online) ; 58: e191073, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1383972

RESUMO

Abstract Gabapentin is an antiepileptic drug prescribed for several neuropathic pain conditions. This study aimed to evaluate gabapentin (GAB) trough plasma concentration range and the applicability of therapeutic drug monitoring in patients with neuropathic pain. Fifty-three patients with neuropathic pain, aged 20 to 75, received gabapentin as treatment for at least 7 days. Gabapentin plasma concentration was sampled before GAB administration and quantified by liquid chromatography with a UV detector. GAB trough plasma concentration ranged between 0.40 and 11.94 µg/mL in patients with chronic neuropathic pain. No differences were observed in terms of GAB plasma concentrations between responsive and non-responsive patients. Our data suggest that the reference ranges suggested in the literature for patients with epilepsy should not be used for patients with neuropathic pain. Therapeutic drug monitoring of GAB was shown to be an important tool to assess treatment adherence.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Pacientes/classificação , Monitoramento de Medicamentos/instrumentação , Gabapentina/análise , Cromatografia Líquida/métodos , Cooperação e Adesão ao Tratamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-34688197

RESUMO

The pharmacokinetic profiling of drug substances and corresponding metabolites in the biological matrix is one of the most informative tools for the treatment efficacy assessment. Therefore, to satisfy the need for comprehensive monitoring of anti-tuberculosis drugs in human plasma, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous quantification of first-line anti-tuberculosis drugs (ethambutol, isoniazid, pyrazinamide, and rifampicin) along with their six primary metabolites. Simple single-step protein precipitation with methanol was chosen as the most convenient sample pre-treatment method. Chromatographic separation of the ten analyte mixture was achieved within 10 minutes on a reverse-phase C8 column using mobile phase gradient mode. The multiple reaction monitoring mode (MRM) was used for analyte detection and quantification in patient samples. The chosen quantification ranges fully covered expected plasma concentrations. The method exhibited acceptable selectivity; the within- and between-run accuracy ranged from 87.2 to 113.6%, but within- and between-run precision was between 1.6 and 14.9% (at the LLOQ level CV < 20%). Although the response of the isonicotinic acid varied depending on the matrix source (CV 21.8%), validation results proved that such inconsistency does not affect the accuracy and precision of results. If stored at room temperature plasma samples should be processed within 4 h after collection, temporary storage at -20 °C up to 24 h is acceptable due to stability issues of analytes. The developed method was applied for the patient sample analysis (n = 34) receiving anti-tuberculosis treatment with the first-line drugs.


Assuntos
Antituberculosos/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Espectrometria de Massas em Tandem/métodos , Tuberculose/tratamento farmacológico , Antituberculosos/sangue , Antituberculosos/uso terapêutico , Monitoramento de Medicamentos/instrumentação , Etambutol/sangue , Etambutol/farmacocinética , Etambutol/uso terapêutico , Humanos , Isoniazida/sangue , Isoniazida/farmacocinética , Isoniazida/uso terapêutico , Plasma/química , Pirazinamida/sangue , Pirazinamida/farmacocinética , Pirazinamida/uso terapêutico , Rifampina/sangue , Rifampina/farmacocinética , Rifampina/uso terapêutico , Tuberculose/sangue
6.
Biol Pharm Bull ; 44(9): 1272-1279, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34471055

RESUMO

The efficacy of infliximab in treating rheumatoid arthritis depends on its serum trough concentration, which must be maintained at a minimum of 1 µg/mL to achieve the desired effects. However, Japan's National Health Insurance system does not cover tests for rheumatoid arthritis patients undergoing treatment with biosimilar infliximab because its performance as a biosimilar remains unclear. This study aimed to investigate whether the Remi-check Q qualitative assay yields comparable results for biosimilar infliximab and the originator product. Infliximab BS 100 "NK" and Remicade 100® were separately diluted in pooled human serum to yield test samples at the following concentrations: 0.30, 0.70, 1.20, and 3.00 µg/mL. Prepared samples were quantitatively assessed using an enzyme-linked immunosorbent assay (ELISA) and qualitatively using Remi-check Q, and the results obtained for the originator and biosimilar product were compared. For both originator and biosimilar infliximab, Remi-check Q yielded a negative result for all 0.30 and 0.70 µg/mL samples and a positive result for all 3.00 µg/mL samples. However, negative results were obtained with a fraction of the 1.20 µg/mL samples (biosimilar, 4/15; originator, 3/15). Concurrence rates between the results of quantitative ELISA and qualitative Remi-check Q analyses were comparable between originator and biosimilar infliximab at all tested concentrations. These results indicate that Remi-check Q yields comparable results for biosimilar infliximab and the originator product on being used as a qualitative assay for trough serum levels.


Assuntos
Bioensaio/instrumentação , Medicamentos Biossimilares/sangue , Monitoramento de Medicamentos/instrumentação , Infliximab/sangue , Kit de Reagentes para Diagnóstico , Artrite Reumatoide/tratamento farmacológico , Medicamentos Biossimilares/administração & dosagem , Medicamentos Biossimilares/farmacocinética , Estudos de Viabilidade , Humanos , Infliximab/administração & dosagem , Infliximab/farmacocinética , Infusões Intravenosas
7.
Rapid Commun Mass Spectrom ; 35(22): e9191, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34490670

RESUMO

RATIONALE: Digoxin is widely used in the clinical treatment of cardiovascular diseases. However, due to its extremely narrow therapeutic window, therapeutic drug monitoring (TDM) is vitally important. In consideration of the time-consuming and labor-intensive nature of the traditional techniques, an automated and efficient method was required for the clinical individualized TDM of digoxin. METHODS: An online solid-phase extraction liquid chromatography tandem high-resolution mass spectrometry (online-SPE-LC-HRMS) method was developed and applied for the determination of digoxin in plasma. The online SPE-LC steps included pretreatment and separation of plasma samples that were carried out using a Waters Oasis HLB cartridge and XBridge Shield RP18 column, respectively. A high-resolution Q Orbitrap mass spectrometer with targeted-selected ion monitoring in negative scan mode was applied to monitor formate-adduct ions [M + HCOO]- m/z 825.42781 for digoxin. RESULTS: Linearity was shown over the range 0.1-10 ng mL-1 for digoxin with correlation coefficients of R2 > 0.999. The lower limit of quantitation (LLOQ) for digoxin was 0.1 ng mL-1 . Extraction recoveries ranged from 82.61% to 94.28% for digoxin. The intra- and inter-day precision values were < 5.53% with accuracy ranging from 84.97% to 96.75%. The total running time was 10 min for each sample. CONCLUSION: The established method displayed satisfactory recoveries, accuracy, precision, and stability, and successfully applied on the TDM of digoxin. This automated streamlined method provides a powerful tool to guide the individualized administration of digoxin, which is significant for the practice of precision medicine.


Assuntos
Automação/métodos , Doenças Cardiovasculares/tratamento farmacológico , Cromatografia Líquida de Alta Pressão/métodos , Digoxina/sangue , Monitoramento de Medicamentos/métodos , Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Antiarrítmicos/sangue , Antiarrítmicos/isolamento & purificação , Antiarrítmicos/uso terapêutico , Digoxina/isolamento & purificação , Digoxina/uso terapêutico , Monitoramento de Medicamentos/instrumentação , Humanos
9.
Transl Behav Med ; 11(3): 842-851, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33710349

RESUMO

Electronic medication monitoring devices (EMD) have been used as a gold standard for assessing medication adherence. We used a wireless EMD (SimpleMed+), assessed its usability in patients after kidney transplantation (KTx), evaluated adherence, and analyzed concordance with other adherence measures. Fifty-five patients (53% female, mean age 46 years) at least 6 months after KTx agreed to use the EMD over a period of 8 weeks. Self-reported adherence was measured with the BAASIS, and immunosuppressant trough level variability was assessed prior to and again during the study period. Fourteen patients stopped using the EMD or were low users (<70%). These non-completers reported that using the EMD would interfere with their daily activities. Taking-adherence of the completers was high with 98.3% (±1.9) over the entire study period. Timing-adherence was somewhat lower (94.6% ± 7.9) and decreased during the second half of the study. We found statistically significant correlations between EMD results and self-reported adherence with moderate effect sizes, but no significant association with trough level variability. The low usage of the EMD supports the need to assess the practicability of an EMD before applying it in research and clinical routine. Taking- and timing-adherence of KTx patients using the EMD was satisfactory. Self-reported adherence might be a good enough estimate of medication adherence.


Assuntos
Monitoramento de Medicamentos/instrumentação , Eletrônica/instrumentação , Imunossupressores/uso terapêutico , Transplante de Rim , Adesão à Medicação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato , Adulto Jovem
10.
ACS Appl Mater Interfaces ; 13(2): 3024-3032, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33404230

RESUMO

A wearable surface-enhanced Raman scattering (SERS) sensor has been developed as a patch type to utilize as a molecular sweat sensor. Here, the SERS patch sensor is designed to comprise a sweat-absorbing layer, which is an interface to the human skin, an SERS active layer, and a dermal protecting layer that prevents damage and contaminations. A silk fibroin protein film (SFF) is a basement layer that absorbs aqueous solutions and filtrates molecules larger than the nanopores created in the ß-sheet matrix of the SFF. On the SFF layer, a plasmonic silver nanowire (AgNW) layer is formed to enhance the Raman signal of the molecules that penetrated through the SERS patch in a label-free method. A transparent dermal protecting layer (DP) allows laser penetration to the AgNW layer enabling Raman measurement through the SERS patch without its detachment from the surface. The molecular detection capability and time-dependent absorption properties of the SERS patch are investigated, and then, the feasibility of its use as a wearable drug detection sweat sensor is demonstrated using 2-fluoro-methamphetamine (2-FMA) on the human cadaver skin. It is believed that the developed SERS patch can be utilized as various flexible and wearable biosensors for healthcare monitoring.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise Espectral Raman/instrumentação , Suor/química , Dispositivos Eletrônicos Vestíveis , Animais , Bombyx/química , Estimulantes do Sistema Nervoso Central/análise , Monitoramento de Medicamentos/instrumentação , Fibroínas/química , Humanos , Metanfetamina/análogos & derivados , Metanfetamina/análise , Nanofios/química , Prata/química , Propriedades de Superfície
11.
Pediatrics ; 147(1)2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33386336

RESUMO

BACKGROUND: Although sensor-based monitoring of daily inhaled corticosteroids (ICSs) and short-acting ß-agonist medications may improve asthma outcomes, the effectiveness of these interventions in diverse pediatric populations remains unclear. METHODS: Caregiver and child dyads were randomly assigned to receive inhaler sensors that allowed for caregiver and clinician electronic monitoring of medications. End points included Asthma Control Test scores (≥19 indicated asthma control) and asthma health care use. Caregiver quality of life (QoL) and child ICS adherence were also assessed. Multilevel models were used to estimate adjusted changes from baseline. RESULTS: Dyads were assigned to the control (n = 127) or intervention (n = 125) arms. At the end line, the mean Asthma Control Test score increased from 19.1 (SE = 0.3) to 21.8 (SE = 0.4) among the intervention and from 19.4 (SE = 0.3) to 19.9 (SE = 0.4) among the control (Δintervention-control = 2.2; SE = 0.6; P < .01). Adjusted rates of emergency department visits and hospitalizations among the intervention were significantly greater (incidence rate ratioemergency department = 2.2; SE = 0.5; P < .01; incidence rate ratiohospital = 3.4; SE = 1.4; P < .01) at endline than the control. Caregiver QoL was greater among the intervention at the endline (Δintervention-control = 0.3; SE = 0.2; P = .1) than the control. CONCLUSIONS: Findings suggest that sensor-based inhaler monitoring with clinical feedback may improve asthma control and caregiver QoL within diverse populations. Higher health care use was observed among the intervention participants relative to the control, indicating further refinement is warranted.


Assuntos
Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Monitoramento de Medicamentos/instrumentação , Adesão à Medicação , Telemetria , Adolescente , Cuidadores/psicologia , Criança , Pré-Escolar , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Monitorização Ambulatorial/instrumentação , Nebulizadores e Vaporizadores , Qualidade de Vida , Smartphone
12.
Crit Rev Anal Chem ; 51(3): 218-231, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31928212

RESUMO

Potentiometry is one of the most important electrochemical methods and potentiometric based sensors have been extensively studied by researchers for many years. The fact that potentiometric sensors have several advantages over other analytical devices is another reason for intensive research on the topic. In this area, hundreds of different sensors have been developed till today and introduced into the literature. The successful use of the developed sensors, particularly in real sample analysis, has made potentiometric sensors the center of attention. In this review, we highlight the studies which have been successfully applied to the developed drug samples and also to many real samples, with high recovery rates.


Assuntos
Potenciometria/métodos , Animais , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Humanos , Eletrodos Seletivos de Íons , Íons/análise , Preparações Farmacêuticas/análise , Potenciometria/instrumentação
13.
Crit Rev Anal Chem ; 51(3): 258-267, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32024370

RESUMO

Apremilast is an anti-inflammatory agent. It has been a flourishing molecule in the field of dermatology. In the year 2014, Apremilast got its approval for treatment of psoriatic arthritis. Presently it is known to treat a number of other conditions, including atopic dermatitis and plaque psoriasis. Apremilast a phthalimide derivative, is non-hygroscopic in nature. It is practically insoluble in water. Apremilast acts by inhibiting the activity of phosphodiesterase 4 (PDE4), an intracellular enzyme. Analytical method plays a key role to understand the physio-chemical properties of a drug molecule. Because of poor solubility and low permeability, analytical method development and formulation becomes challenging. Till date, there are no standard test methods available to analyze Apremilast. So, a critical review of the analytical techniques of Apremilast was carried out. The literature search was done by screening the papers reporting analytical techniques of Apremilast from year 2014 to 2019. Methodologies particularly UV spectroscopy, HPTLC, HPLC, X-ray diffraction, NMR, LC-MS were collected and reviewed. Interminable efforts are made by the researchers to develop simple, accurate, robust and cost-effective methods of analysis. In pharmaceutical research, this information will aid in the development of new delivery systems. The review will prove beneficial and advantageous pre-formulation studies and will guide the formulation development.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Técnicas de Química Analítica/métodos , Monitoramento de Medicamentos/métodos , Talidomida/análogos & derivados , Animais , Anti-Inflamatórios não Esteroides/farmacocinética , Artrite Psoriásica/tratamento farmacológico , Técnicas de Química Analítica/instrumentação , Cromatografia/instrumentação , Cromatografia/métodos , Monitoramento de Medicamentos/instrumentação , Humanos , Análise Espectral/instrumentação , Análise Espectral/métodos , Talidomida/análise , Talidomida/farmacocinética
14.
Crit Rev Anal Chem ; 51(3): 268-277, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32048875

RESUMO

Hypertension is commonly a quiet condition, and it expands the risk of heart diseases and stroke. Calcium delivers a substantial role in cardiovascular functions and hence is essential for cardiac automaticity and functioning. Calcium channel antagonists are the choice of drugs for the management of cardiovascular diseases; they precisely stop the introduction of calcium through L-type calcium channels are existing channels in the heart. Cilnidipine belongs to the class 4th generation calcium channel blockers as a foremost therapeutic agent used in the treatment of hypertension and heart diseases. This review article focuses on an inclusive account of crucial analytical methodologies used for the pharmaceutical analysis of cilnidipine in pure forms, biological samples and pharmaceuticals. According to literature reports several analytical techniques such as hyphenated techniques, high-performance thin-layer chromatography, high-performance liquid-chromatography, capillary electrophoresis, voltammetry, UV/Vis-spectrophotometry, and Fourier-transform infrared spectroscopy approaches have been used for determination of cilnidipine alone or in the combined dosage form. We have also discussed the pharmacopeial assay methods, physicochemical properties, and also depict the stacked column chart for year wise publication count for cilnidipine. From literature, concluded that the high-performance liquid-chromatography and UV/Vis-spectrophotometry methods are the most prevailing methods for the analysis of cilnidipine. The data presented in this review may provide a very significant base for further studies on cilnidipine in the area of drug analysis.


Assuntos
Bloqueadores dos Canais de Cálcio/análise , Di-Hidropiridinas/análise , Animais , Bloqueadores dos Canais de Cálcio/farmacocinética , Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Di-Hidropiridinas/farmacocinética , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Humanos , Hipertensão/tratamento farmacológico
15.
Crit Rev Anal Chem ; 51(3): 232-245, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31899949

RESUMO

Fexofenadine hydrochloride is an antihistamine agent used for the treatment of allergic disorders like rhinitis. It is a second generation antihistamine. Montelukast sodium is an anti-asthmatic agent and leukotriene receptor antagonist used in the treatment of respiratory disorders. This article exemplifies the reported analytical methods like electrometric methods, ultraviolet spectroscopy, mass spectroscopy, thin layer chromatography, high performance liquid chromatography, high performance thin layer chromatography and tandem spectroscopy for determination of fexofenadine HCl and montelukast sodium in dosage form and in biological matrices. This review covers almost all the analytical methods for fexofenadine hydrochloride and montelukast sodium form 1968-2018 years. Complete analytical validation parameters reported are discussed in this review for both analytes. Among various analytical methods, HPLC and UV-visible spectrophotometry were found to be the most extensively used methods by the researchers.


Assuntos
Acetatos/análise , Antialérgicos/análise , Técnicas de Química Analítica/métodos , Ciclopropanos/análise , Monitoramento de Medicamentos/métodos , Antagonistas de Leucotrienos/análise , Quinolinas/análise , Sulfetos/análise , Terfenadina/análogos & derivados , Acetatos/farmacocinética , Animais , Antialérgicos/farmacocinética , Antiasmáticos/análise , Antiasmáticos/farmacocinética , Técnicas de Química Analítica/instrumentação , Ciclopropanos/farmacocinética , Monitoramento de Medicamentos/instrumentação , Antagonistas não Sedativos dos Receptores H1 da Histamina/análise , Antagonistas não Sedativos dos Receptores H1 da Histamina/farmacocinética , Humanos , Antagonistas de Leucotrienos/farmacocinética , Quinolinas/farmacocinética , Sulfetos/farmacocinética , Terfenadina/análise , Terfenadina/farmacocinética
16.
Thromb Haemost ; 121(1): 58-69, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32877954

RESUMO

BACKGROUND: There are acute settings where assessing the anticoagulant effect of direct oral anticoagulants (DOACs) can be useful. Due to variability among routine coagulation tests, there is an unmet need for an assay that detects DOAC effects within minutes in the laboratory or at the point of care. METHODS: We developed a novel dielectric microsensor, termed ClotChip, and previously showed that the time to reach peak permittivity (T peak) is a sensitive parameter of coagulation function. We conducted a prospective, single-center, pilot study to determine its clinical utility at detecting DOAC anticoagulant effects in whole blood. RESULTS: We accrued 154 individuals: 50 healthy volunteers, 49 rivaroxaban patients, 47 apixaban, and 8 dabigatran patients. Blood samples underwent ClotChip measurements and plasma coagulation tests. Control mean T peak was 428 seconds (95% confidence interval [CI]: 401-455 seconds). For rivaroxaban, mean T peak was 592 seconds (95% CI: 550-634 seconds). A receiver operating characteristic curve showed that the area under the curve (AUC) predicting rivaroxaban using T peak was 0.83 (95% CI: 0.75-0.91, p < 0.01). For apixaban, mean T peak was 594 seconds (95% CI: 548-639 seconds); AUC was 0.82 (95% CI: 0.73-0.91, p < 0.01). For dabigatran, mean T peak was 894 seconds (95% CI: 701-1,086 seconds); AUC was 1 (p < 0.01). Specificity for all DOACs was 88%; sensitivity ranged from 72 to 100%. CONCLUSION: This diagnostic study using samples from "real-world" DOAC patients supports that ClotChip exhibits high sensitivity at detecting DOAC anticoagulant effects in a disposable portable platform, using a miniscule amount of whole blood (<10 µL).


Assuntos
Testes de Coagulação Sanguínea/instrumentação , Monitoramento de Medicamentos/instrumentação , Inibidores do Fator Xa/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Coagulação Sanguínea/efeitos dos fármacos , Testes de Coagulação Sanguínea/métodos , Dabigatrana/farmacologia , Dabigatrana/uso terapêutico , Monitoramento de Medicamentos/métodos , Desenho de Equipamento , Inibidores do Fator Xa/farmacologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pirazóis/farmacologia , Pirazóis/uso terapêutico , Piridonas/farmacologia , Piridonas/uso terapêutico , Rivaroxabana/farmacologia , Rivaroxabana/uso terapêutico
18.
Anal Bioanal Chem ; 413(2): 599-612, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33155133

RESUMO

A liquid chromatography tandem mass spectrometry method for the analysis of ten kinase inhibitors (afatinib, axitinib, bosutinib, cabozantinib, dabrafenib, lenvatinib, nilotinib, osimertinib, ruxolitinib, and trametinib) in human serum and plasma for the application in daily clinical routine has been developed and validated according to the US Food and Drug Administration and European Medicines Agency validation guidelines for bioanalytical methods. After protein precipitation of plasma samples with acetonitrile, chromatographic separation was performed at ambient temperature using a Waters XBridge® Phenyl 3.5 µm (2.1 × 50 mm) column. The mobile phases consisted of water-methanol (9:1, v/v) with 10 mM ammonium bicarbonate as phase A and methanol-water (9:1, v/v) with 10 mM ammonium bicarbonate as phase B. Gradient elution was applied at a flow rate of 400 µL/min. Analytes were detected and quantified using multiple reaction monitoring in electrospray ionization positive mode. Stable isotopically labeled compounds of each kinase inhibitor were used as internal standards. The acquisition time was 7.0 min per run. All analytes and internal standards eluted within 3.0 min. The calibration curves were linear over the range of 2-500 ng/mL for afatinib, axitinib, bosutinib, lenvatinib, ruxolitinib, and trametinib, and 6-1500 ng/mL for cabozantinib, dabrafenib, nilotinib, and osimertinib (coefficients of correlation ≥ 0.99). Validation assays for accuracy and precision, matrix effect, recovery, carryover, and stability were appropriate according to regulatory agencies. The rapid and sensitive assay ensures high throughput and was successfully applied to monitor concentrations of kinase inhibitors in patients. Graphical abstract.


Assuntos
Cromatografia Líquida/métodos , Plasma/metabolismo , Inibidores de Proteínas Quinases/sangue , Espectrometria de Massas em Tandem/métodos , Calibragem , Técnicas de Química Analítica , Química Farmacêutica , Cromatografia , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Humanos , Limite de Detecção , Espectrometria de Massas , Reprodutibilidade dos Testes , Razão Sinal-Ruído
19.
Int J Mol Sci ; 21(22)2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-33233561

RESUMO

Thalassemia syndromes are characterized by the inability to produce normal hemoglobin. Ineffective erythropoiesis and red cell transfusions are sources of excess iron that the human organism is unable to remove. Iron that is not saturated by transferrin is a toxic agent that, in transfusion-dependent patients, leads to death from iron-induced cardiomyopathy in the second decade of life. The availability of effective iron chelators, advances in the understanding of the mechanism of iron toxicity and overloading, and the availability of noninvasive methods to monitor iron loading and unloading in the liver, heart, and pancreas have all significantly increased the survival of patients with thalassemia. Prolonged exposure to iron toxicity is involved in the development of endocrinopathy, osteoporosis, cirrhosis, renal failure, and malignant transformation. Now that survival has been dramatically improved, the challenge of iron chelation therapy is to prevent complications. The time has come to consider that the primary goal of chelation therapy is to avoid 24-h exposure to toxic iron and maintain body iron levels within the normal range, avoiding possible chelation-related damage. It is very important to minimize irreversible organ damage to prevent malignant transformation before complications set in and make patients ineligible for current and future curative therapies. In this clinical case-based review, we highlight particular aspects of the management of iron overload in patients with beta-thalassemia syndromes, focusing on our own experience in treating such patients. We review the pathophysiology of iron overload and the different ways to assess, quantify, and monitor it. We also discuss chelation strategies that can be used with currently available chelators, balancing the need to keep non-transferrin-bound iron levels to a minimum (zero) 24 h a day, 7 days a week and the risk of over-chelation.


Assuntos
Desferroxamina/administração & dosagem , Quelantes de Ferro/administração & dosagem , Sobrecarga de Ferro/tratamento farmacológico , Ferro/metabolismo , Reação Transfusional/complicações , Talassemia beta/terapia , Adulto , Transfusão de Sangue , Cardiomiopatias/sangue , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Cardiomiopatias/prevenção & controle , Terapia por Quelação/efeitos adversos , Terapia por Quelação/métodos , Desferroxamina/efeitos adversos , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Feminino , Coração/efeitos dos fármacos , Coração/fisiopatologia , Humanos , Ferro/toxicidade , Quelantes de Ferro/efeitos adversos , Sobrecarga de Ferro/sangue , Sobrecarga de Ferro/complicações , Sobrecarga de Ferro/fisiopatologia , Fígado/efeitos dos fármacos , Fígado/metabolismo , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Pâncreas/efeitos dos fármacos , Pâncreas/metabolismo , Pâncreas/patologia , Transferrina/metabolismo , Reação Transfusional/sangue , Reação Transfusional/fisiopatologia , Talassemia beta/metabolismo , Talassemia beta/patologia
20.
Crit Care ; 24(1): 664, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33239110

RESUMO

BACKGROUND: Effective antimicrobial treatment is key to reduce mortality associated with bacterial sepsis in patients on intensive care units (ICUs). Dose adjustments are often necessary to account for pathophysiological changes or renal replacement therapy. Extracorporeal membrane oxygenation (ECMO) is increasingly being used for the treatment of respiratory and/or cardiac failure. However, it remains unclear whether dose adjustments are necessary to avoid subtherapeutic drug levels in septic patients on ECMO support. Here, we aimed to evaluate and comparatively assess serum concentrations of continuously applied antibiotics in intensive care patients being treated with and without ECMO. METHODS: Between October 2018 and December 2019, we prospectively enrolled patients on a pneumological ICU in southwest Germany who received antibiotic treatment with piperacillin/tazobactam, ceftazidime, meropenem, or linezolid. All antibiotics were applied using continuous infusion, and therapeutic drug monitoring of serum concentrations (expressed as mg/L) was carried out using high-performance liquid chromatography. Target concentrations were defined as fourfold above the minimal inhibitory concentration (MIC) of susceptible bacterial isolates, according to EUCAST breakpoints. RESULTS: The final cohort comprised 105 ICU patients, of whom 30 were treated with ECMO. ECMO patients were significantly younger (mean age: 47.7 vs. 61.2 years; p < 0.001), required renal replacement therapy more frequently (53.3% vs. 32.0%; p = 0.048) and had an elevated ICU mortality (60.0% vs. 22.7%; p < 0.001). Data on antibiotic serum concentrations derived from 112 measurements among ECMO and 186 measurements from non-ECMO patients showed significantly lower median serum concentrations for piperacillin (32.3 vs. 52.9; p = 0.029) and standard-dose meropenem (15.0 vs. 17.8; p = 0.020) in the ECMO group. We found high rates of insufficient antibiotic serum concentrations below the pre-specified MIC target among ECMO patients (piperacillin: 48% vs. 13% in non-ECMO; linezolid: 35% vs. 15% in non-ECMO), whereas no such difference was observed for ceftazidime and meropenem. CONCLUSIONS: ECMO treatment was associated with significantly reduced serum concentrations of specific antibiotics. Future studies are needed to assess the pharmacokinetic characteristics of antibiotics in ICU patients on ECMO support.


Assuntos
Antibacterianos/análise , Monitoramento de Medicamentos/métodos , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Terapia de Substituição Renal/estatística & dados numéricos , Adulto , Idoso , Antibacterianos/administração & dosagem , Antibacterianos/sangue , Ceftazidima/administração & dosagem , Ceftazidima/análise , Ceftazidima/sangue , Monitoramento de Medicamentos/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Alemanha , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Linezolida/administração & dosagem , Linezolida/análise , Linezolida/sangue , Masculino , Meropeném/administração & dosagem , Meropeném/análise , Meropeném/sangue , Pessoa de Meia-Idade , Combinação Piperacilina e Tazobactam/administração & dosagem , Combinação Piperacilina e Tazobactam/análise , Combinação Piperacilina e Tazobactam/sangue , Estudos Prospectivos , Terapia de Substituição Renal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...